Steelcraft 4-0
Comsense - eCatalog Info

Syndication

Useful Links

CATALOG/PRICING/OEW INFORMATION
Complete Steelcraft Update 4-0
December 3, 2008

DOORS

Graintech revised to price and validate in AHM and OEW, Enterprise/Advantage

Louver Cutouts and Louvers Installed

Special size louver as an installed option is no longer available
Location is always top of door to top of cutout
Numerous new options for installed louvers
Louver/Cutout Location Method is no longer an option
Location will always be from top of door to top of cutout

NOTE: User must also select the required louver(s) from the Louvers Installed table

Valid Louver Cutouts Only
SF8616 - F-LCOB-NC - LVR Cutout Bottom No Chan
SF9094 - F-LCOB-WC - LVR Cutout Bottom w/Chan
SF8618 - F-LCOT-NC - LVR Cutout Top No Chan
SF9200 - F-LCOT-WC - LVR Cutout Top w/Chan
SF8620 - F-L2CO-NC - LVR Cutouts Top/Bottom No Chan
SF8621 - F-L2CO-WC - LVR Cutouts Top/Bottom w/Chan

Louver Cutout in Bottom of Door with Channel Installed

Step#1 - Select required door type



Step #2 - Select the required prep and continue with takeoff



Step #3 - F2 in the Opening Notes field to reveal required attributes



Step #4 - Enter dimensions as required (Channel attribute is autmatically applied)



Step # 5 - F9 to save attributes, F9 to exit prep and add on window.



Valid Door Types forLouvers Installed

SF7860 - F-LLIB-NC - LVR Install Bottom No Chan
SF7862 - F-LLIB-WC - LVR Install Bottom w/Chan
SF7869 - F-LLIBS-NC - LVR Install Bottom w/Screen No Chan
SF7872 - F-LLIBS-WC - LVR Install Bottom w/Screen w/Chan
SF7864 - F-LLIT-NC - LVR Install Top No Chan
SF7867 - F-LLIT-WC - LVR Install Top w/Chan
SF7870 - F-LLITS-NC - LVR Install Top w/Screen No Chan
SF7873 - F-LLITS-WC - LVR Install Top w/Screen w/Chan
SF7866 - F-L2LI-NC - LVR Install Top/Bottom No Chan
SF7868 - F-L2LI-WC - LVR Install Top/Bottom w/Chan
SF7871 - F-L2LIS-NC - LVR Install Top/Bot w/Screen No Chan
SF7874 - F-L2LIS-WC - LVR Install Top/Bot w/Screen w/Chan

Louver installed in bottom of door with channel

Step#1 - Select required door type



Step #2 - No required preps. Conitnue with takeoff. F2 in prep and add on Code field for table list



Step #3 - Select Louvers Installed table



Step #4 - Select required louver



Step #5 - Enter dimension as required - F9 to save, F9 to exit prep and add on window



L Series 1 3/4" Transom Panels

Revised to price and validate in OEW
Various panels with options are listed in the Door TYPE table
Instructions below are only for information specific to panels (gauge or material as required)

Step #1 - Select thickness '4'

Step #2 - Select HMP in the DESC field



Step #3 - Select LP Series



Step #4 - Select panel type



Step #5- Select Core 'HC,STY,URE' (URE not available labeled) Continue with takeoff



LP - L Series Panel Options 

Options Non Labeled OMIT SCREWS or OMIT ASTRAGAL
SELECT ONLY IF YOU WANT TO OMIT ONE OR BOTH
Label Options - WHA, WHB, WHC, WHS and CONST-D & ULP (Transom frame without bar only)
OMIT SCREWS option is not available on labeled panels without a transom bar

OLP Open Edge Laminated Panels

Non-Labeled

Step #1 - Select Thickness 3/8



Step #2 - Select HMP from DESC field



Step #3 - Select Series OLP



Step #4 - Select Type LP38



Step #5 - Select Core FC. Continue with takeoff



OLP Open Edge Laminated Panels

For installation in labeled Sidelites, Borrowed lites, etc.
These panels are not ordered as labeled. Leave LAB field blank. The frame label applies to the panel

Step #1 - Select Thickness 1/2



Step #2 and Step #3 same as 3/8 panel

Step #4 - Select Type LP12



Step #5 - Select Core MC



No Longer Available

Door Handing - DA - A valid hand must be entered
Cores - STIFF/CG164-007, STIFF/OMIT CORE
Trim Type - CUT OUT RECESSED

Dutch Doors

Step #1 - Select Door Type



Step #2 - Select Shelf & Astragal Options - If no shelf is required do not select



Step #3 - Select Dutch Hinge Preps



Note: All labeled Dutch doors are considered to have special hardware locations which are to be entered in Prep Notes field.

Step #4 - Select Dutch Lock Preps



NOTE: OEW issue with labeled Dutch lock  prep - Will not pass at this time


Continuous Hinge Preps - Important Information

SF6424 - CH-EDGE Reinforced on STANDARD width door (NOT UNDERSIZED)
It is assumed that FRAME IS OVERSIZED
No other options available

SF6425 - CH-FACE Reinforced on STANDARD width door (NOT UNDERSIZED)
It is assumed that the hinge is FULL SURFACE
No other options available

SF6044 - CHR Reinforced per MFR and PART# (UNDERSIZED IF REQUIRED)
Manufacturer Code and Part number required for proper reinforcement location and door size
NOTE: Use this option when UNDERSIZED DOORS are required

New Table - Floor Clearance/Undercut
Preps from 1/8" through 2" applied as a hardware prep to threshold.

NOTE - ADVANTAGE ONLY:

Using these preps on paired openings does not apply the undercut to the inactive leaf.
In this case please use the Prep code SF1402 in Engineered Options
This allows user input for undercut from 1/8" through 4" as Hollow Metal prep

FRAMES

Cased Open Frames with hardware preps for 1 3/4 and 1 3/8 doors

EXAMPLES:
NSF10976 - SGL-CO F 16 CO-4 534 3070 CRS KD
SF2009   - CO45U         4 1/2 UNIVERSAL
SF2012   - ASA-CO       ASA

NSF10976 - SGL-CO F 16 CO-8 534 3070 CRS KD
SF2017   - CO-4SW       4 STD WT
SF2012   - ASA-CO       ASA

Communicating Frames are available with the following door sizes and hands:

2 - 1 3/4 Doors
2 - 1 3/8 Doors
L\R - LH/RH
R\L - RH/LH
L\L - LH/LH
R\R - RH/RH

No Longer Available

Thermal Break Sections
12ga Open Sections
LS Doors
FS Frames
All reference to LS doors and FS frames have been removed from the tables

New Deadlock Preps:

ASA-48, ASA-60,ASA-SP
CYL (T-STRIKE)-48, CYL (T-STRIKE)-60,CYL (T-STRIKE)-SP

Unequal Face Jambs and Head

Frames with unequal faces are ordered KD
Furnished square cut for welding by distributor - (NOT DIE MITERED)
Can also be ordered factory welded

AHM USERS

If you receive a message regarding conflicting attributes for TYPE please enter C to continue.
One example of this is shown below. There will be similar situations.
The proper information will be passed in OEW and prints on the PO as well.
This situation will be corrected with an update in December


Posted 11-27-2008 3:45 PM by Jim Butler
Copyright 2008 Comsense Inc. 202-7145 West Credit Ave. Bldg 2, Mississauga, ON L5N 6J7 Tel: 905-542-9300
Powered by Community Server (Non-Commercial Edition), by Telligent Systems