CURRIES Complete Update 8-0
April 30, 2008
-
Reminders
The cost of standard anchors has been removed from all M, CM, MK, CMK and all HJ, SJ, COJ
You must select a standard anchor even when estimating to obtain correct pricing
The cost of a standard closer reinforcement has been removed from label pricing
You must select a standard closer when pricing labeled frame and doors.
-
Major changes/additions for Windstorm Products
New entries in Certification table for DC, UL and WH design pressure codes
New entries in Windstorm Construction Requirements
New entries in Label table for UL and WH Label for Windstorm product without a fire rating
New/Revised StormPro 361 products
Frame series changed to M361
Double frame with removable mullion must be built as an elevation.
CCW blank jamb and blank mullion will have to be replaced with the following
NCC9919 – HJ M361
NCC9920 – HDR M361
NCC9921 – RMULL M361
StormPro Pricing Page 15 – DBL Outswing #1
There is product built for a 5 3/4 Jamb Depth that does not contain pricing
Curries was unable to verify if a range up to 5 3/4 was available at this time
Please contact your customer service representative for pricing and availability
-
Anchors for FEMA 320/361 Frames - Revised
The following two anchor preps must be used together
FMJ - Masonry T Anchors Jambs FEMA 320/361 – Prints M on PO
FWPSH – WPS Anchors in Head FEMA 320/361 – Prints WPS on PO
The following anchor prep is used alone
FWPSJH – WPS Anchors Jambs/Head FEMA 320/361 – Prints WPS on PO
-
Anchors for Standard Hurricane Windstorm Frames
Select the appropriate number of anchors as indicated at the bottom of Windstorm frame prices
That is the number that is circled which is one of the following: 8, 10, 12 or 18
Failure to select the proper number of anchors will result in incorrect pricing
Additional Windstorm Anchors for CCW Windstorm pricing are as follows
M16 Masonry T Windstorm BL/SL Jamb <5’0”
M32 Masonry T Windstorm BL/SL Jamb 5’0”>
M20 T or WM Windstorm Transom Frame
WPS1 – WPS 1 Per LF in Head/Sill Windstorm CCW
WPS1A – WPS 1 every 16” Width and Height
-
Added new Product- Expandable Drywall Frame
Available From Service Centers
EXP-1 5 1/2" thru 8 3/4"
EXP-2 8 1/2" thru 13 1/4”
Added new Material
A40 for Expandable Frames Only
-
Added Eng-Misc Preps/Electric box with knockouts
CC7500-HJ
CC7501-SJ
CC7502-HDR
-
Added Eng-Misc Preps/ Box Only
CC7503-HJ
CC7504-SJ
CC7505-HDR
-
Deleted from frame table-ENG MISC
CC5245 Electric box with knockouts
CC5247 Box Only
Please use new options noted above
-
Added CURRIStain TYPE 2 lite kits to door type
-
CCW93,97,101,105,94,98,102 & 106 changed from 16 to 18 gauge
New Cut & Notch Prep - P115 (Weld cap on jamb & finish)
-
New prep CC 6549 2 coats Std Gray Prime to Paint/ Prefinish Table (Frame Table)
New prep CC7544 2 coats Std. Gray Prime to Paint/ Prefinish Table (Door Table )
-
Deleted Electrolynx preps LX6 thru LX15 from tables (no longer available)
-
H1T - Duplicate prep in door Lock Table has been removed. Use H1
Removed prep H1** - Flushbolt prep Top or Bottom with user entry required
New Prep H1TOP (1 @ Top) and H1BOT (1 @ Bottom) as default
Removed SB SGL – Single Surface Bolt Reinforcement with user entry required
Replaced with – SBTOP (1 @Top) and SBBOT (1 @ Bottom) as default
-
Removed centerline requirement for mail slot cutout in embossed panel door
There is only one location for this prep
-
Frame Table – Eng Misc.
Removed DE SBE, DE SBW – Price from CCW material built as an Elevation
Removed duplicate QC Cable prep CC6076. Use prep CC7220
-
Frame Table – CONS
Removed SMO/3F, SBE3F, SMW/3F, SBW3F. These are to be price from CCW material built as an Elevation
-
Revised Windstorm approval numbers Table WS - FLA for both doors and frames
Posted
04-30-2008 3:50 PM
by
Jim Butler