Curries 7-5
Comsense - eCatalog Info

Syndication

Useful Links

CURRIES

November 20, 2007

Partial Update 7-5

The following changes are included in this update:

HINGE PREPS

Correction made to hinge defaults. Some hinge preps were showing a quantity of 3, 4, etc. and should be showing a quantity of 1 because the hinge preps are based on specific quantities in lieu of individual

This has been corrected.

DOOR TYPES

Addition of new ENG types and explanation of pricing difference between standard and engineered

In the example below of existing door types, FV would be used to order a standard FV type with no variations. This gets you a door with cutout and kit installed.

The FV-ENG would be used to order a non-standard FV with special options such as cutout only, or cutout and channel, location, etc., and all pertinent information must be provided by the user

For ENG types you must select all required preps from the LITES/LVR/ENG table to obtain a correct price. AHM users must enter required preps, notes etc. Properties have been assigned for advantage users to enter the required information but preps must also still be selected.

CC1201    FV               Standard Vision Lite Type 1 10"x10"                   CC1200 112.00

CC2150    FV-ENG       Engineered - Molding/Cutout/Channel                 CC1200       

The following louver type examples are similar to the above with one exception. The charge for F2L only gives you pricing for cutouts only. You must add (2) 12” x 12” louvers. If you do not add the louvers when you select the F2L, F3L, etc., the factory is going to provide them regardless and, your cost will be more than what the Purchase Order indicates

CC1721    F2L             2 - 12" x 12" Cutouts *ADD LOUVERS*           CC1200 48.00

CC7414    F2L-ENG    2 - Spec Cutouts, Location *ADD LOUVERS*   CC1200       

CC7416    F3L-ENG    3 - Spec Cutouts, Location *ADD LOUVERS*   CC1200       

CC7424    F4L-ENG    4 - Spec Cutouts, Location *ADD LOUVERS*   CC1200

DOOR LABELS

The following label types have been added to the Fire table for doors.

G          1 Hour

D         UL 1 1/2 Hour Exterior Use

E          UL 3/4 Hour Exterior Use

Advantage Users

We received a report that when the SLS (Special Location Strike) prep was selected it was being applied to the active leaf in lieu of the inactive leaf. This was tested and the problem could not be recreated. However, we have made a change to these records to update the date last changed in case there was an issue there. If anyone is still having problems with the preps in the LOCK/SL Table please contact support immediately.


Posted 11-19-2007 3:59 PM by Jim Butler